XEEPL is one of the Leading Manufacturer, Supplier & Exporter of the Industrial Instrumentation Lab Equipment. We Manufacture Displacement measurement using LVDT, Measurement of negative pressure using McLeod gauge Mcleod Gauge, Pressure Measurement by using Bourdon Tube, Temperature measurement using Thermocouple, Flow rate Measurement by using Rota-meter, Liquid Level measurement by Capacitive transducer, measurement of Speed, Stroboscope, Strain Gauge using cantilever beam etc..

Also We do manufacture the Test Rigs as per customers requirement.

At XEEPL, we understand the dynamics of each customer requirement and the variety of demands of Their Experimental & Research system. We help you with innovative design that makes the system more Reliable, Robust, cost-effective and economical in long run, saving substantially on your power and maintenance cost.

At XEEPL, All the equipments & systems are thoroughly tested before delivery to ensure that they function without problems. Service plays a crucial role in day-to-day dealings with our customers. Therefore, you can take it for granted that we always provide you with exact Instant support.

Our commitment to quality, innovation and after-sale support has helped us to maintain a strong market position and develop a reputation for industry leadership.

Strain Gauge Setup

REQUEST CALLBACK

Strain Gauge Setup
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 15,000 / PieceGet Latest Price

Product Details:
Minimum Order Quantity01 Piece
Power Supply230 V
BrandXEEPL
Operating Frequency50Hz
Display TypeLED
The system is designed forMaximum of 5-kg load
Accuracy+/- 1%
Nominal Value120 Ohm

STRAIN GAUGE SETUP: With cantilever beam:

  • Four no. of strain gage with a nominal value of 120 ohm / 350 ohms are mounted on a cantilever beam which can be loaded with the help of weights in a pan.
  • The system is designed for a maximum of 5-kg load and can be used as a load cell also.
  • Detailed calculations regarding stress and strain in the beam can be performed.
  • Provision is made for two- arm and four-arm operation.
  • Bridge balance controls in terms of coarse control and fine control are provided.
  • An amplifier with a variable gain in the range of 0 to 1000 is used for signal processing.
  • Accuracy: +/- 1%


Additional Information:

  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Nhava Sheva
  • Production Capacity: 50
  • Delivery Time: 1-2 Weeks
Yes! I am Interested

Calibration Of Temperature Measuring Instrument

REQUEST CALLBACK

Calibration Of Temperature Measuring Instrument
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Application/UsageIndustrial
Instruments to be RepairedYes
Calibrated ForEnd User
Preferred Measuring TypeMetric
Calibration IntervalYearly
Industry TypeManufacturer
ConditionNew
ThermocoupleRange 0 to200 degree C. Accuracy: +/- 1% of the range.
ThermistorOnly characteristics with two ranges (0 to 2000 ohm & 0 to 20 K ohm) selectable by switch.
RTDusing PT 100 with provision for study of temp. Versus resistance and temp. (I/P) with indicated temp
IC SensorIC Sensor AD 590 is used to study its application as temp. Sensor. Range 0 to 200 degree C.

Calibration of Temp. Measuring Instrument:

This set up is designed to enable the student to study the following sensors.

  • Thermocouple: Range 0 to200 degree C. Accuracy: +/- 1% of the range.
  • Thermistor: Only characteristics with two ranges (0 to 2000 ohm & 0 to 20 K ohm) selectable by switch.
  • RTD: using PT 100 with provision for study of temp. Versus resistance and temp. (I/P) with indicated temp. Characteristics of this widely sensor. Range 0 to 200 degree C. with an accuracy of +/- 1% of the range.
  • IC Sensor: IC Sensor AD 590 is used to study its application as temp. Sensor. Range 0 to 200 degree C. the system comes with water container, heater with cable thermometer. It is housed in an elegant powder coated MS box with neatly labeled anodized plate with suitable connecting terminals IC Sensor: IC Sensor AD 590 is used to study its application as temp. Sensor. Range 0 to 200 degree C. the system comes with water container, heater with cable thermometer. It is housed in an elegant powder coated MS box with neatly labeled anodized plate with suitable connecting terminals
Yes! I am Interested

Displacement Measurement Using LVDT

REQUEST CALLBACK

Displacement Measurement Using LVDT
  • Displacement Measurement Using LVDT
  • Displacement Measurement Using LVDT
  • Displacement Measurement Using LVDT
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
LVDT Using Ordinary ScaleThis transducer enables measurement of mechanical displacement in the range of 20 mm
fiber glass housing and magnetic core along with primary and secondary windings 30-cm
An overall accuracybetter than 2%

Displacement measurement using linear variable differential Transformer: LVDT Using Ordinary Scale: This transducer enables measurement of mechanical displacement in the range of 20 mm using an ordinary scale. Provision is made for 30-cm long fiber glass housing and magnetic core along with primary and secondary windings. An overall accuracy better than 2% of full scale is provided. Appropriate test points are also provided for observation of waveforms. Primary excitation at 4 kilohertz and 1 volt RMS is used.
Yes! I am Interested

Thermocouple Setup

REQUEST CALLBACK

Thermocouple Setup
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
DPM200mv.
Thermocouple for the range 0 to 100 degree C
heater1 kW

To plot the Characteristics of Thermocouple:

Panel provisions:
  • DPM 200mv.
  • Thermocouple suitable for the range 0 to 100˚C will be supplied along with the set up.
  • In order to perform the temperature measurement (ie thermocouple, RTD and Thermistor) a water container along with 1 kW heater, cable will be supplied as a common accessory for all these experiments.
  • A standard laboratory thermometer will also be supplied. Accuracy: +/- 1.5%
Yes! I am Interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
Xtreme Engineering Equipment Private Limited
Ganesh Chandak (Director)
Survey No. 37/02, Ashtavinayak Industrial Estate, Parvati Nagar Dhayari Narhe Road,
Pune - 411041, Maharashtra, India
Call Us: 
Call Response Rate: 71%
Share Us :
F G T L



Home  |   Company Brief   |  Our Products  |  Site Map  |   Contact Us

© Xtreme Engineering Equipment Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Xtreme Engineering Equipment Private Limited